To allow for cost comparison across different sources, ASHRAE 90.2 and DEER original datasets are converted from 2008 to 2011 dollars using the National Construction Cost Index.
For regional cost adjustment please use Location Factors.
General Information
| Uniformat Code | ||
|---|---|---|
| Component | Wood-Framed Floor | |
| Building Type | Multi-Family | |
| Building Section | Shell | B |
| Category | Substructure | B10 |
| Construction | Floor Construction | B1010 |
| Description | Structural Frame | B101001 |
| Tags | 10 inch Fiberglass Batt, Kraft Face, Secured in place, 2x12, Joist at 24 inch on center | |
| Data Source | ASHRAE 90.2 | |
| Location Type | National | |
| Building Category | Envelope | |
| Description | Floors | |
| Version Year | 2011 |
Energy Measures
| U Factor | 0.033 |
| Cavity R Value | 30 |
Cost Data
| Labor Cost | Cost Unit | Material Costs | Installation Cost | Equipment Cost | Total Cost |
|---|---|---|---|---|---|
|
| $/ft2
| 4.7
|
|
| 4.7 |
Notes
Component u-factor has been estimated using the REScheck-Web software tool version 4.4.1; 2008 dataset Indexed into 2011$