From BC3
Home » Component Database » All Wood Joist Truss Roof » All Wood Joist Truss Roof (0013)
To allow for cost comparison across different sources, ASHRAE 90.2 and DEER original datasets are converted from 2008 to 2011 dollars using the National Construction Cost Index.
For regional cost adjustment please use Location Factors.
General Information
| Uniformat Code | ||
|---|---|---|
| Component | All Wood Joist Truss Roof | |
| Building Type | Multi-Family | |
| Building Section | Shell | B |
| Category | Superstructure | B10 |
| Construction | Roof Construction | B1020 |
| Description | Structural Frame | B102001 |
| Tags | 2x4 & 2x4 Std, Heel 4-1/8, 24 inch on center, 6/12 Flat Ceiling, 14 inch soffit | |
| Data Source | ASHRAE 90.2 | |
| Location Type | National | |
| Building Category | Envelope | |
| Description | Roofs | |
| Version Year | 2011 |
Energy Measures
| U Factor | 0.051 |
| Cavity R Value | 19 |
Cost Data
| Labor Cost | Cost Unit | Material Costs | Installation Cost | Equipment Cost | Total Cost |
|---|---|---|---|---|---|
|
| $/ft2
| 4.18
|
|
| 4.18 |
Notes
Component u-factor has been estimated using the REScheck-Web software tool version 4.4.1; 2008 dataset Indexed into 2011$